ECGAnnotationTypeMDC
[2.16.840.1.113883.1.11.19335] Content from code system(s): Description: ISO 11073-10101 Health informatics - Point-of-care device codes, restricted to ECG category names |
||||
Lvl | Content Type | Code System | Primary Reference | Qualifiers/Identifiers |
---|---|---|---|---|
0 | content | ISO 11073-10101 Health informatics - Point-of-care | OpenIssue: TODO: To make this content computable, represent the defining statement as either a property filter or a computable expression filter. The defining statement in the vocabulary data base is: "Restricted to ECG Category Names" |
ECGBeatTypeMDC
[2.16.840.1.113883.1.11.19337] Content from code system(s): Description: ISO 11073-10101 Health informatics - Point-of-care device codes, restricted to ECG Beat Types |
||||
Lvl | Content Type | Code System | Primary Reference | Qualifiers/Identifiers |
---|---|---|---|---|
0 | content | ISO 11073-10101 Health informatics - Point-of-care | OpenIssue: TODO: To make this content computable, represent the defining statement as either a property filter or a computable expression filter. The defining statement in the vocabulary data base is: "Restricted to ECG Beat Types" |
ECGContourObservationTypeMDC
[2.16.840.1.113883.1.11.19341] Content from code system(s): Description: ISO 11073-10101 Health informatics - Point-of-care device codes, restricted to ECG Observation Types |
||||
Lvl | Content Type | Code System | Primary Reference | Qualifiers/Identifiers |
---|---|---|---|---|
0 | content | ISO 11073-10101 Health informatics - Point-of-care | OpenIssue: TODO: To make this content computable, represent the defining statement as either a property filter or a computable expression filter. The defining statement in the vocabulary data base is: "Restricted to Countour Observation Types" |
ECGControlVariableMDC
[2.16.840.1.113883.1.11.19336] Content from code system(s): Description: ISO 11073-10101 Health informatics - Point-of-care device codes, restricted to ECG Control Variables |
||||
Lvl | Content Type | Code System | Primary Reference | Qualifiers/Identifiers |
---|---|---|---|---|
0 | content | ISO 11073-10101 Health informatics - Point-of-care | OpenIssue: TODO: To make this content computable, represent the defining statement as either a property filter or a computable expression filter. The defining statement in the vocabulary data base is: "Restricted to ECG Control Variables" |
ECGLeadTypeMDC
[2.16.840.1.113883.1.11.19334] Content from code system(s): Description: ISO 11073-10101 Health informatics - Point-of-care device codes, restricted to ECG Lead Types |
||||
Lvl | Content Type | Code System | Primary Reference | Qualifiers/Identifiers |
---|---|---|---|---|
0 | content | ISO 11073-10101 Health informatics - Point-of-care | OpenIssue: TODO: To make this content computable, represent the defining statement as either a property filter or a computable expression filter. The defining statement in the vocabulary data base is: "Restricted to ECG Lead Types" |
ECGNoiseTypeMDC
[2.16.840.1.113883.1.11.19340] Content from code system(s): Description: ISO 11073-10101 Health informatics - Point-of-care device codes, restricted to ECG Noise Types |
||||
Lvl | Content Type | Code System | Primary Reference | Qualifiers/Identifiers |
---|---|---|---|---|
0 | content | ISO 11073-10101 Health informatics - Point-of-care | OpenIssue: TODO: To make this content computable, represent the defining statement as either a property filter or a computable expression filter. The defining statement in the vocabulary data base is: "Restricted to ECG Noise Types" |
ECGRhythmTypeMDC
[2.16.840.1.113883.1.11.19339] Content from code system(s): Description: ISO 11073-10101 Health informatics - Point-of-care device codes, restricted to ECG Rhythm Types |
||||
Lvl | Content Type | Code System | Primary Reference | Qualifiers/Identifiers |
---|---|---|---|---|
0 | content | ISO 11073-10101 Health informatics - Point-of-care | OpenIssue: TODO: To make this content computable, represent the defining statement as either a property filter or a computable expression filter. The defining statement in the vocabulary data base is: "Restricted to ECG Rhythm Types" |
ECGWaveComponentTypeMDC
[2.16.840.1.113883.1.11.19338] Content from code system(s): Description: ISO 11073-10101 Health informatics - Point-of-care device codes, restricted to ECG Waveform Component Types |
||||
Lvl | Content Type | Code System | Primary Reference | Qualifiers/Identifiers |
---|---|---|---|---|
0 | content | ISO 11073-10101 Health informatics - Point-of-care | OpenIssue: TODO: To make this content computable, represent the defining statement as either a property filter or a computable expression filter. The defining statement in the vocabulary data base is: "Restricted to ECG Waveform Component Types" |
Last Published: 20120831 10:21 AM
HL7® Version 3 Standard, © 2012 Health Level Seven® International. All Rights Reserved.
HL7 and Health Level Seven are registered trademarks of Health Level Seven International Reg. U.S. Pat & TM Off.